Airtightness Solutions

You can insulate a leaky house perfectly and still be cold.

Airtight Is Not the Same as Unventilated

Air comes in where you decide, not wherever the wind finds a gap.

Insulation slows heat moving through the building fabric. It does nothing about heat leaving with air that escapes through gaps, cracks and unsealed junctions — and in a typical older Irish home, that uncontrolled leakage is a substantial part of the heat loss.

This is the misunderstanding that puts people off, so it’s worth being clear: an airtight building is not a sealed box. It’s a building where air comes in and goes out where you decide, through a ventilation system designed for the purpose, rather than randomly through gaps you can’t control, carrying heat with it.

Controlled ventilation gives you better air quality than leakage ever did, because it works consistently instead of depending on which way the wind is blowing. Airtightness and ventilation are designed together, always.

Where Buildings Actually Leak

Rarely one big hole. Usually dozens of small, predictable paths.

Air leakage is rarely one big hole. It’s dozens of small paths, and the usual offenders are consistent:

  • Service penetrations — pipes, cables and ducts through walls, floors and ceilings
  • The junction where walls meet the ground floor and the ceiling
  • Around window and door frames, behind the internal finish
  • Attic hatches and recessed downlighters
  • Unsealed suspended floors
  • Chimneys and redundant flues
  • Behind kitchen units, baths and shower trays, where the finish never got sealed

Explore More

Home & Energy Services

From insulation to heat pumps, ventilation and more. Improve comfort, lower bills and increase your BER rating.

Design & Build

New builds, extensions and deep retrofits, fully managed from design and planning through to construction and completion.

Solar PV

High-quality solar panel systems for homes, farms and businesses. Lower energy costs and gain energy independence.

Sectors

Energy upgrades and construction solutions for commercial, agricultural and public sector projects.

Testing — The Blower Door

A blower door test puts the building under controlled pressure and measures the air changing per hour. It gives you a number to work against, and it’s how compliance is demonstrated on new builds and deep retrofits.

More useful than the number, in a retrofit, is what the test reveals. With the building under pressure we can walk it and find the leaks — with smoke, with thermal imaging, and by hand. That turns airtightness from an abstraction into a specific list of things to seal. We carry out testing at two stages on larger projects: an early test while the fabric is still accessible and problems are cheap to fix, and a final test for certification.

Sealing the building

Once leakage paths are identified, sealing uses the right material for each junction — membranes, tapes, grommets, expanding seals and airtight-grade sealants, applied to surfaces prepared to take them. Ordinary decorator’s filler and expanding foam do not make a building airtight. They’re what you find when a previous job failed.

Builder working on blockwork at a new build site

Frequently Asked Questions

Will making my house airtight cause condensation?

Not if ventilation is designed alongside it. It’s when buildings are tightened without ventilation being addressed that problems appear. We assess both together.

What’s a good airtightness result?

It depends on the building and what it’s being certified against. New build and NZEB targets are considerably more demanding than what a typical retrofit achieves. We’ll set a realistic target for your project at survey.

Can you test a house that’s already finished?

Yes. The test works on any completed building — though sealing what it finds is easier when finishes are still open.

Is airtightness work grant supported?

It’s generally delivered as part of a wider upgrade rather than as a standalone grant measure. Ask us and we’ll tell you how it sits in your project.

Book an airtightness test.

Call 051 850722 to discuss your project. We test, find the leaks, and seal them properly.

Why ENCON

Testing that produces a list of fixes, not just a number.